Description
  • Large OLED Display
    Displays resistance mantissa and exponent, temperature, relative humidity and test voltage
  • Internal Memory
    Stores and recalls up to 100 measurements. Captures resistance, temperature, humidity and test voltage.
  • Measurement Stability Modes
    Sets the 15-second electrification period for test requirements*
  • Electrode Spacers
    Spaces the 5 lbs. electrodes to 10 and 36 inches for resistance point-to-point (Rtt) measurement requirements of ANSI/ESD S.1 and ANSI/ESD S4.1
  • Measurement Location Labels (Pack of 25)
    Labels and tracks areas and materials measured for surface resistance
  • Digital Compliance Verification Surface Resistance Meter Kit
    Measures resistance point-to-point (Rtt) and resistance-to-ground (Rtg) of worksurfaces, flooring systems, garments, packaging, and other materials in accordance with ESD Association documents: ESD TR53, ANSI/ESD S4.1, ANSI/ESD S7.1, ANSI/ESD STM97.1 and others
  • Resistance Range: 1.0 x 103 to 1.0 x 1012 Ohms
    Determines if a surface is conductive, dissipative or insulative for ESD control applications in electronics manufacturing or handling environments
  • Under Load Test Voltages (10V or 100V ±5%)
    Meets ANSI/ESD S20.20 resistance testing requirements for product qualification and compliance verification
  • 770007 Concentric Ring Probe Accessory
    Measures surface resistance per ANSI/ESD STM11.11 and volume resistance per ANSI/ESD STM11.12 of planar material
  • 770765 Handheld Electrode Accessory
    Meets resistance measurement requirements of TR53, ANSI/ESD STM97.1 and other documents
  • NIST Calibrated with Certificate Included
    Calibrated with accepted procedures and standards traceable to the National Institute of Standards and Technology. For more information on the calibration of SCS products, see Calibration
  • Made in the United States of America

 

Kit Includes:
1 Digital Surface Resistance Meter
2 Test Leads, 5' Length
2 5 lbs. Electrodes
1 Electrode Spacer, 10"
1 Electrode Spacer, 36"
4 AA Alkaline Batteries
1 Ground Plug Adapter
1 Gator Clip
25 Measurement Location Labels
1 Plastic Carrying Case
1 Certificate of Calibration

 

*Measurement Stability Modes:
Auto Stabilization enables a 15-second electrification period when the measured resistance is 1 x 1010 ohms or greater to maintain test accuracy.
Fixed Stabilization complies with ANSI/ESD S4.1 and enables a 15-second electrification period when the measured resistance is 1 x 106 ohms or greater.