Description
What it is. Among Ansell AlphaTec gloves, the 38-612 is a pair of unsupported butyl gloves with a Viton layer, made for handling aggressive chemicals. Each glove is 12 inches (300 mm) long, finished smooth, and closed with a beaded cuff that gives the opening a firm edge. Ansell's data sheet notes that the style was previously sold as ChemTek 38-612, so older purchasing records may list it under that name. LabPro supplies it in sizes 8, 9, and 10, with 36 pairs in every case.
Why it matters. A glove that resists one solvent family can fail against another, so chemical work often means swapping gloves mid-task. Butyl and Viton cover different ground, and this glove layers them, so buyers comparing Viton gloves with butyl rubber gloves get both materials in one pair. Ansell states that it protects against aliphatic, halogenated, and aromatic hydrocarbons as well as concentrated mineral acids. Ansell lists chemical processing, oil refining, and HazMat work among its uses.
How it performs. The wall measures 0.30 mm (about 11.8 mil), and Ansell shapes the glove with a natural curve and soft feel that ease donning and doffing while maintaining dexterity. It is antistatic under EN 1149, latex- and silicone-free, and carries an EN ISO 374-1 Type A rating, meaning it was tested against a defined set of chemicals rather than simply described as resistant. It is Category III PPE, with EN ISO 374-5 cover for bacteria and fungi.
Materials and packing. The glove is a black Viton and butyl polymer, unsupported and unlined. The build is roughly 4 mil of Viton over 8 mil of butyl. Each SKU is a single size sold as a case of 36 pairs, so one case suits a team that wears the same size. Because these Viton butyl gloves are built for aggressive chemicals rather than general use, check each chemical against Ansell's guidance before stocking a size.
Technical Specifications
| Manufacturer | Ansell |
| Series and model | AlphaTec 38-612 (previously ChemTek 38-612) |
| Product type | Chemical-resistant gloves, unsupported |
| Material | Viton / butyl polymer |
| Layer build | About 4 mil Viton over 8 mil butyl |
| Thickness | 0.30 mm (11.8 mil) |
| Length | 300 mm (11.8 in) |
| Color | Black |
| Grip surface | Smooth finish |
| Cuff | Beaded |
| Lining | Unlined |
| Sizes | 8, 9, 10 |
| Latex | Latex free |
| Silicone | Silicone free |
| Antistatic | Yes, EN 1149 |
| Chemical protection standard | EN ISO 374-1 Type A, test chemical codes BCFLPST |
| Micro-organism protection | EN ISO 374-5, bacteria and fungi only |
| PPE category | Category III |
| Pack count | 36 pairs per case |
Available Variants
- 38612080: Size 8, 36 pairs per case
- 38612090: Size 9, 36 pairs per case
- 103212: Size 10, 36 pairs per case
The three SKUs differ only in glove size, and all three hold 36 pairs of the same butyl and Viton glove.
Applications / Common Uses
- Liquid and solid transfers. Moving material between vessels, tanks, and process equipment exposes hands to splashes, and the 0.30 mm Viton and butyl wall acts as a barrier against the hydrocarbons and mineral acids Ansell lists.
- Loading and unloading process equipment. The 12-inch length reaches past the wrist, and the beaded cuff gives the opening an edge, which suits work that involves reaching and handling.
- Handling incoming goods. Receiving areas can meet a leaking container without warning, so a glove tested against several chemical families adds a buffer at the dock.
- Inspection and part checking. The soft feel and curved ergonomic shape support the dexterity needed to pick, select, and check parts while chemicals are present.
- Spill and leak response. Ansell lists unexpected leaks, spills, and releases among recommended uses, which fits a glove tested to the Type A chemical standard.
Storage, Handling & Shipping
AlphaTec 38-612 gloves are supplied as sized pairs, 36 pairs in each LabPro case, and each pair is packed with its own information insert. Keep the gloves in the carton with their inserts until they are issued, and follow the storage guidance in Ansell's technical data sheet and Instructions for Use.
- Check each glove for visible damage before use and retire any that show cuts, tears, or changes in texture.
- Wear the right size: this style is made only in sizes 8, 9, and 10, with no smaller size.
- Keep the data sheet with the stock record so the chemical list and standards stay with the case.
- Order by case: each SKU holds 36 pairs of a single size.
Related Categories & Services
These LabPro pages help buyers compare this butyl and Viton glove with related products, choose companion items, and plan recurring supply.
- Cleanroom Gloves: LabPro's cleanroom glove range, for comparing this butyl and Viton glove with cleanroom glove styles.
- Gloves: LabPro's main gloves page, for comparing this butyl and Viton glove with other glove materials and types.
- Safety Supplies: LabPro's safety supplies page, for pairing this butyl and Viton glove with other protective equipment.
- Spill Protection: LabPro's spill protection products, relevant because this butyl and Viton glove is chosen for chemical work where splashes and spills are a risk.
- Chemicals & Reagents: LabPro's chemicals and reagents page, for buyers who also source materials for the same work.
- VMI Program (service): LabPro's vendor-managed inventory program, relevant for teams that reorder this butyl and Viton glove on a regular schedule.
Related Articles
FAQs
Butyl vs Viton gloves: why does this glove use both?
Butyl is generally chosen for ketones and esters, while Viton is generally chosen for aromatic and chlorinated solvents. Ansell layers Viton over butyl so one pair spans more chemical families than either material alone. No single glove resists every chemical, so check your own chemicals and concentrations against Ansell's guidance first.
What do the EN ISO 374-1 Type A and BCFLPST codes mean?
Type A means breakthrough took at least 30 minutes against six or more of the standard's test chemicals. The letters B, C, F, L, P, S, and T name acetone, acetonitrile, toluene, 96% sulfuric acid, 30% hydrogen peroxide, 40% hydrofluoric acid, and 37% formaldehyde, the seven this glove is listed against.
How do I check these gloves for damage before each use?
Inspect each glove for cuts, pinholes, swelling, tackiness, or discoloration, and flex the fingers to reveal cracks. Because the build is unsupported and unlined, damage can show quickly, but breakthrough can occur without visible signs, so replace gloves on a schedule after chemical contact, not only when they look worn.
Does the antistatic listing make the glove safe near flammable solvents?
EN 1149 tests the electrostatic properties of protective clothing, so the listing describes charge behavior, not a rating for flammable atmospheres. Before using the glove near flammable solvents, check your site's hazardous-area rules and ask Ansell for electrostatic data, then pair the glove with chemical guidance for your own process.
Can I rely on the chemical rating for my own process?
Treat the rating as a starting point. Breakthrough time shifts with chemical, concentration, temperature, and contact time, and Ansell states that it takes no responsibility for suitability in a specific application. Match the glove to your own risk assessment and test it under real conditions.