• What it is. These accelerator-free nitrile gloves are Ansell Nitrilite 93-401, a non-sterile, powder-free glove for Class 10 (ISO 4) cleanrooms. The nitrile is formulated without latex proteins or chemical accelerators, and Ansell reports very low ionic content and particulate levels. Each glove has textured fingers and a powder-free interior. LabPro lists six glove sizes from X-Small through 2X-Large, with 1,000 gloves in every case, plus an extra 2X-Large SKU.
  • Why it matters. Type I and Type IV allergic reactions have different triggers: latex proteins for the first and curing accelerators for the second. Ansell removes both from the 93-401 formulation, which can matter for staff who have reacted to other gloves in the past. The low ionic content and particulate levels also suit work where residue counts, and Ansell lists life sciences and electronics as target applications for this glove.
  • How it performs. Freedom from holes is held to a 1.5 AQL. The interior is powder-free and chlorinated, and the glove measures 300 mm (12 inches) long, with a palm of about 4.3 mil and fingers of about 5.1 mil. Ansell lists conformity to EN ISO 374-1 and 374-5, Category III, and FDA 21 CFR 177.2600, and the glove is made under ISO 9001:2015 quality management. The cuff is beaded, the fingers are textured, and the color is natural.
  • Materials and packing. Gloves are packed 50 to an inner bag, with two inner bags per master polybag and ten master polybags per liner bag, for a total of 1,000 gloves per case. The material is nitrile with no natural rubber latex. Because the glove is non-sterile, it controls particles rather than microorganisms, so pair it with a sterile glove where aseptic work is required. Ansell recommends it for cleanroom cleaning and preparation.

Applications / Common Uses

  • Cleanroom cleaning and preparing. Ansell recommends the glove for this task, where the Class 10 (ISO 4) rating and low particulate levels protect the room.
  • Life sciences work. Ansell lists life sciences as an application, and the accelerator-free formulation lowers allergy risk for staff gloved all day.
  • Electronics handling. Ansell lists electronics as an application, and the low ionic content helps limit residues on sensitive surfaces.
  • Biotechnology and medical device settings. Biotechnology and medical device settings are listed uses, where non-sterile cleanroom gloves control particles during handling.
  • Staff with prior glove reactions. The formulation is free of latex proteins and accelerators to reduce the risk of Type I and Type IV allergic reactions.

Technical Specifications

  • Manufacturer: Ansell
  • Series and model: Nitrilite 93-401, clean nitrile glove
  • Product type: Non-sterile cleanroom nitrile glove
  • Material: Nitrile
  • Color: Natural
  • Accelerators: None (accelerator-free)
  • Latex proteins: None (free of latex proteins)
  • Powder: Powder-free
  • External surface: Textured fingers
  • Internal surface: Powder-free, chlorinated
  • Cuff: Beaded
  • Length: 300 mm (12 in)
  • Thickness: Palm 4.3 mil, finger 5.1 mil
  • Sterility: Non-sterile
  • Cleanroom class: Class 10 / ISO 4
  • Freedom from holes: 1.5 AQL (EN 455-1 / ASTM D3577)
  • Standards listed: Category III; EN ISO 21420:2020; EN ISO 374-1:2016; EN ISO 374-5:2016; FDA 21 CFR 177.2600
  • Quality standard: ISO 9001:2015
  • Sizes: X-Small, Small, Medium, Large, X-Large, 2X-Large
  • Packaging: 50 per inner bag; 2 inner bags per master polybag; 10 master polybags per liner bag
  • Pack count: 1,000 gloves per case

Available Variants

  • 104945: X-Small, 1,000 gloves per case
  • 104946: Small, 1,000 gloves per case
  • 104947: Medium, 1,000 gloves per case
  • 104948: Large, 1,000 gloves per case
  • 104949: X-Large, 1,000 gloves per case
  • 104950: 2X-Large, 1,000 gloves per case
  • 104955: 2X-Large (10.0 to 10.5, liner bag), 1,000 gloves per case

The seven SKUs differ by glove size, and each holds 1,000 gloves. Two SKUs, 104950 and 104955, both cover 2X-Large; the second is listed with a size range of 10.0 to 10.5 and packed in a liner bag.

Storage, Handling & Shipping

The gloves are supplied non-sterile and for single use. They are packed 50 gloves per inner bag and 1,000 gloves per case. The listed shelf life is five years, with cartons kept out of direct sunlight, stored in a cool, dry place, and kept away from sources of ozone or ignition.

  • Keep gloves in their inner bags until use to protect cleanliness.
  • Use each glove once, and discard after use.
  • Order by case: every SKU holds 1,000 gloves of one size.
  • Confirm the 2X-Large size, which has two SKUs, before placing an order.

Related Categories & Services

These LabPro pages help buyers compare these accelerator-free nitrile gloves with related products, choose companion items, and plan recurring supply.

  • Gloves: LabPro's main gloves page, for comparing these accelerator-free nitrile gloves with other glove materials and types.
  • Cleanroom and Critical Environment: LabPro's cleanroom and critical environment page, covering the products used alongside these accelerator-free nitrile gloves in controlled areas.
  • Glove Selection Guide: LabPro's glove selection guide, for matching glove material and protection level to the task.
  • VMI Program (service): LabPro's vendor-managed inventory program, relevant for teams that reorder these accelerator-free nitrile gloves on a regular schedule.

Related Articles

FAQs