Description
What they are. LabClean Cellulose/Polyester Cleanroom Wipes are nonwoven cleanroom wipes made from a hydroentangled blend of 55% cellulose and 45% polyester. They pair cellulose's natural absorbency with polyester's strength and low linting, giving controlled environments an economical, absorbent wipe for everyday cleaning. LabClean is Lab Pro's own wipe line, and these wipes come in 4 × 4 in., 9 × 9 in., and 12 × 12 in. sizes.
Built for absorbency. The cellulose fibers pull in liquid fast: LabClean lists a sorptive rate of about 0.3 seconds, so the wipe picks up solvents, disinfectants, and spills almost on contact. That speed matters for wipe-downs with isopropyl alcohol or other cleaners, because a wipe that absorbs quickly carries contamination away instead of smearing it across the surface. Low levels of extractables help keep residues from transferring onto what is being cleaned. For cleanroom staff, that means fewer passes and less solvent per surface cleaned.
Low linting and edge design. The hydroentangled construction locks fibers together without chemical binders, and cold-knife cut edges help minimize particle generation along the borders. LabClean rates these lint-free wipes for moderate particle counts and ISO Class 6–7 cleanroom environments (Class 1,000–10,000). For tighter ISO Class 5–6 areas, Lab Pro's wiper selection guide points to the LabClean 100% polyester knit wipes with laser-cut edges. That combination keeps them practical for high-volume, everyday cleaning.
Cleanroom packaging. LabClean wipes are laundered and packaged in a cleanroom, then vacuum-packed in solvent-safe, cleanroom-compatible polyethylene with an inner bag label. Vacuum packing keeps the stack compact and clean until the bag is opened at the point of use, and the inner label stays readable once the outer packaging is removed. The packaging format makes it easy to bring wipes into gowned areas without adding contamination. Labeled inner bags also help with lot tracking during audits.
Where they are used. LabClean lists cleanroom wipe-down at ISO Class 6–7, electronics displays, instrument panels, medical devices, and semiconductors and microelectronics among typical uses. Lab Pro supplies them to pharmaceutical cleanrooms, CDMO and pharma services companies, biotech labs, electronics makers, and industrial facilities. Aerospace, healthcare, laboratory, manufacturing, and packaging operations also use them for routine contamination control on benches, tools, and equipment. One wipe type can therefore cover many routine tasks across a facility.
Choosing a size. The 4 × 4 in wipe suits small parts, tools, and detail cleaning, while the 9 × 9 in and 12 × 12 in sizes cover benches, equipment surfaces, and spills. You can fold larger wipes into quarters to get several clean faces per wipe, which helps you follow a one-direction, overlapping wiping pattern. Bulk case quantities let facilities stock high-use sizes without frequent reordering. Keeping two or three sizes on hand covers most cleaning jobs in a typical controlled environment.
Technical Specifications
| Brand | LabClean (Lab Pro) |
| Material | 55% cellulose / 45% polyester |
| Fabric Type | Hydroentangled (spunlace) nonwoven |
| Edge Style | Cold-knife cut |
| Cleanroom Compatibility | ISO Class 6–7 (Class 1,000–10,000) |
| Sorptive Rate | ~0.3 seconds |
| Basis Weight | 56–68 g/m² (see note) |
| Particles / Extractables | Moderate particle counts; low extractables |
| Sizes | 4 × 4 in · 9 × 9 in · 12 × 12 in |
| Processing | Laundered and packaged in a cleanroom |
| Packaging | Vacuum-packed in solvent-safe, cleanroom-compatible polyethylene with inner bag label |
Available Variants
- LC-CPWIPE4X4: 4 × 4 in; bag of 1,200 (also sold as a case of 12,000)
- LC-CPWIPE9X9: 9 × 9 in; bag of 300 (case of 3,000)
- LC-CPWIPE12X12: 12 × 12 in; bag of 300 (case of 3,000)
All three sizes use the same 55% cellulose / 45% polyester nonwoven and cleanroom packaging; they differ only in wipe size and pack count, so facilities can match the wipe to the surface being cleaned.
Applications / Common Uses
- Cleanroom wipe-downs: routine surface cleaning in ISO Class 6–7 areas
- Solvent and disinfectant application: fast-absorbing wipe for IPA and cleaning agents
- Electronics and displays: cleaning displays, instrument panels, and microelectronics
- Medical device and pharma production: contamination control in pharmaceutical and device manufacturing
- Spill cleanup: rapid uptake of liquid spills on benches and equipment
Storage, Handling & Shipping
Store unopened LabClean bags in a clean, dry area away from dust and chemicals. Open bags at the point of use, ideally inside the controlled area, and reseal or use partial bags promptly to keep remaining wipes clean. Do not return used wipes to the bag. Dispose of wipes according to what they were used to clean, following your facility's procedures for solvent-wetted or contaminated wipes.
- Storage: Clean, dry area; unopened until use
- Opening: Open at the point of use inside the controlled area
- Disposal: Per facility rules for the chemicals or contaminants picked up
Related Categories & Services
- LabClean Wipes: Lab Pro's own LabClean wipe line in blend and polyester options
- Non-Sterile Wipers: cleanroom wipers to pair with solvents for wipe-downs
- Sterile Wipers: sterile wipers for aseptic and critical areas
- Non-Sterile IPA: isopropyl alcohol for general cleanroom wiping and cleaning
- Cleanroom Swabs: swabs for detail cleaning in tight spots
- Cleanroom Manufacturing industry page: Lab Pro products used in cleanroom manufacturing
Services
- Need recurring supply? Ask about Vendor-Managed Inventory (VMI) for standing orders of cleanroom wipes
- Punchout Catalogs: order through your procurement system
- Vending Machine Solutions: on-site vending for frequently used supplies
Technical Library
FAQs
What is the difference between cellulose/polyester and 100% polyester cleanroom wipes?
Cellulose/polyester blends absorb liquid faster and cost less, making them suitable for ISO Class 6–7 areas and general wipe-downs. 100% polyester knit wipes release fewer particles and fibers, so they are preferred in tighter ISO Class 5–6 areas and for critical surfaces. Choose by cleanroom class and how much absorbency the task needs.
How should a cleanroom wipe be used for best results?
Fold the wipe to create several clean faces, wipe in one direction with slightly overlapping strokes, and turn to a fresh face often instead of scrubbing back and forth. Work from cleaner areas to dirtier ones and from top to bottom so you remove contamination rather than redistribute it.
Can these wipes be used with isopropyl alcohol?
Yes. The wipes absorb solvents and disinfectants quickly, and LabClean vacuum-packs them in solvent-safe polyethylene. Dampen the wipe rather than flooding it, so the surface stays wet for the required contact time without pooling excess solvent. Discard wipes once they are visibly soiled.
Are LabClean cellulose/polyester wipes sterile?
The sources reviewed describe them as laundered and packaged in a cleanroom, not as sterile. If your process requires sterile wipes, such as in aseptic areas, confirm with Lab Pro before use or choose a wipe specifically labeled and validated as sterile. Ask for documentation if needed.
Why do cleanroom wipes have special edges?
Cut edges are where fibers and particles most easily shed. Cold-knife cutting on these nonwoven wipes limits fraying, while knit polyester wipes often use laser- or heat-sealed edges for even lower particle release. Edge treatment is one reason cleanroom wipes outperform ordinary shop towels. Match edge type to cleanroom class.















