Description
What they are. LabClean 100% Polyester Cleanroom Wipes are knit polyester wipes made from 100% virgin, continuous-filament polyester in a double-knit, no-run interlock construction. They are Lab Pro's LabClean wipe for tighter controlled environments, rated for ISO Class 5–6 (Class 100–1,000) cleanrooms. The wipes come in 4 × 4 in, 9 × 9 in, and 12 × 12 in sizes for detail cleaning, tools, benches, and equipment surfaces in critical areas.
Why continuous-filament polyester. Continuous-filament yarn has no short staple fibers that can work loose, and the no-run interlock knit keeps the fabric from unraveling, so these polyester wipes shed far fewer particles and fibers than nonwoven or cellulose wipes. LabClean lists low levels of particulate and extractables, along with moderate absorbency and abrasion resistance, giving a durable wipe that can scrub surfaces without breaking down. That durability also means fewer wipes per job.
Laser-sealed edges. Edges are where wipes shed the most. LabClean cuts these wipes with a laser that melts and seals the fiber ends, which reduces fiber contamination compared with cold-knife cut edges. Lab Pro's wiper selection guide explains that a laser-sealed edge is cleaner because all the fiber ends are melted, which is why laser-cut polyester knits are the standard choice in ISO 5 and ISO 6 areas. Edge quality is one of the clearest differences between cleanroom and general-purpose wipes.
Absorbency and cleanliness data. LabClean publishes test data for the wipe: a basis weight of 120 g/m² (TAPPI T-410), a sorptive capacity of 310 mL/m², and a sorptive rate under 1 second, measured by IEST-RP-CC004.3. The wipes are laundered and packaged in an ISO Class 5 cleanroom, then vacuum-packed in solvent-safe, cleanroom-compatible polyethylene with an inner bag label, so they arrive ready for gowned areas. Published test methods let quality teams compare wipes on a like-for-like basis.
Where they are used. LabClean lists cleanroom wipe-down at ISO Class 5–6, electronics displays, instrument panels, medical devices, and semiconductors and microelectronics among their uses, with aerospace, electronics, and laboratory operations among the industries served. The wipes work dry for dust and particle removal or wetted with isopropyl alcohol and other cleanroom solvents, which the solvent-safe packaging and polyester construction tolerate well. Fold each wipe to expose fresh faces as it collects contamination.
Polyester or cellulose blend? Choose these 100% polyester wipes when particle and fiber release matter most, such as in ISO 5–6 cleanrooms and on optics, displays, and wafers. For ISO 6–7 areas and high-absorbency tasks like spill cleanup, LabClean's 55% cellulose / 45% polyester nonwoven wipe is the more economical option. Many facilities stock both, matching each wipe to its cleanroom class and task. Clear labeling of each wipe type helps staff pick correctly.
Technical Specifications
| Brand | LabClean (Lab Pro) |
| Material | 100% virgin, continuous-filament polyester |
| Knit Type | Double-knit, no-run interlock |
| Edge Design | Laser-cut, sealed |
| Cleanroom Compatibility | ISO Class 5–6 (Class 100–1,000) |
| Basis Weight | 120 g/m² (TAPPI T-410) |
| Sorptive Capacity | 310 mL/m² (IEST-RP-CC004.3) |
| Sorptive Rate | <1 second |
| Particles / Extractables | Low levels |
| Laundering / Packaging Environment | ISO Class 5 cleanroom |
| Packaging | Vacuum-packed, solvent-safe polyethylene with inner bag label |
| Sizes | 4 × 4 in · 9 × 9 in · 12 × 12 in |
Available Variants
- LC-PWIPE4X4: 4 × 4 in; bag of 600
- LC-PWIPE9X9: 9 × 9 in; bag of 150
- LC-PWIPE12X12: 12 × 12 in; bag of 150
All three sizes use the same 100% polyester double-knit fabric, laser-sealed edges, and ISO Class 5 laundering; they differ only in wipe size and wipes per bag.
Applications / Common Uses
- ISO 5–6 cleanroom wipe-downs: low-particle surface cleaning in critical areas
- Semiconductors and microelectronics: wiping wafers, tools, and process equipment
- Displays and optics: cleaning displays, instrument panels, and optical surfaces
- Medical device manufacturing: contamination control on parts and work surfaces
- Solvent wiping: dry or wetted with IPA and cleanroom solvents
Storage, Handling & Shipping
Keep LabClean bags sealed in a clean, dry area until use, and open them at the point of use inside the controlled area. Take wipes out with gloved hands, reseal partially used bags or use them promptly, and never return used wipes to the bag. Dispose of used wipes according to the solvents or contaminants they picked up and your facility's waste procedures.
- Storage: Sealed; clean, dry area
- Opening: At the point of use, inside the controlled area
- Handling: Gloved hands; do not return used wipes
- Disposal: Per facility rules for solvents or contaminants
Related Categories & Services
- LabClean Wipes: Lab Pro's own LabClean wipe line in blend and polyester options
- Sterile Wipers: sterile wipers for aseptic and critical areas
- Non-Sterile Wipers: cleanroom wipers to pair with solvents for wipe-downs
- Non-Sterile IPA: isopropyl alcohol for general cleanroom wiping and cleaning
- Cleanroom Swabs: swabs for detail cleaning in tight spots
- Cleanroom Manufacturing industry page: Lab Pro products used in cleanroom manufacturing
Services
- Need recurring supply? Ask about Vendor-Managed Inventory (VMI) for standing orders of cleanroom wipes
- Punchout Catalogs: order through your procurement system
- Vending Machine Solutions: on-site vending for frequently used supplies
Technical Library
FAQs
Why are knit polyester wipes used in ISO 5 cleanrooms?
Continuous-filament knit polyester releases very few fibers and particles, and laser-sealed edges keep the borders from shedding. That combination keeps contamination low enough for ISO Class 5 work, where nonwoven or cellulose wipes would add too many particles to critical surfaces. They suit critical surfaces as well.
What does "sorptive rate" mean for a wipe?
Sorptive rate is how quickly the wipe takes up liquid, and sorptive capacity is how much it can hold. LabClean lists a rate under 1 second and a capacity of 310 mL/m², so the wipe picks up solvent fast instead of pushing it across the surface. Fast uptake supports single-pass cleaning.
Can polyester cleanroom wipes be reused?
In cleanrooms, wipes are typically single-use: once a wipe has collected contamination, reusing it can redeposit particles. Fold wipes to use several clean faces, then discard them. Laundered reusable wipes exist, but they follow a separate cleaning and qualification process. Follow your cleanroom SOP.
Which size should I choose?
Use 4 × 4 in wipes for small parts, tools, and detail work, and 9 × 9 in or 12 × 12 in wipes for benches and equipment. Larger wipes can be folded into quarters, giving several clean faces per wipe for a one-direction wiping pattern. Keep both sizes stocked.
Are these wipes sterile?
The sources describe them as laundered and packaged in an ISO Class 5 cleanroom, not as sterile. For aseptic areas that require sterile wipes, confirm with Lab Pro before use or choose a wipe labeled and validated as sterile, such as a gamma-irradiated polyester wipe. Ask for documentation if required.