Description
What it is. These sterile sleeve covers are the Ansell BioClean-D S-BDSC-L, a longer-length sleeve cover supplied sterile for cleanroom gowning. Ansell gives an average length of 480 mm, which adds coverage over the arms compared with its standard sleeve covers. They are made from low-linting, lightweight CleanTough material and have an integrated thumb loop. LabPro sells the style in a universal size, as a case of 90 pairs, each pair sealed in its own bag.
Why it matters. Sleeve covers close the gap between a glove cuff and a garment, and a longer cover reaches further up the forearm. Ansell says the integrated thumb loop keeps the sleeve from rolling back and exposing the arm or wrist. The cover is sterile with a sterility assurance level of 10⁻⁶, so it suits gowning sequences in which every layer that touches the work area has to be sterile.
How it performs. Each pair is gamma irradiated, and Ansell lists a shelf life of three years from the date of manufacture. Ansell's sheet gives liquid repellency above 90 percent, rated 3 under ISO 6530, for four test liquids including 30 percent sulfuric acid and 10 percent sodium hydroxide, and the standards include EN 13034:2005 with A1:2009, EN 1149-5:2018, and ISO 11137-1:2006, with Category III and UKCA marking. The fabric also carries an antistatic coating with a charge half-decay time of 0.07 seconds.
Materials and packing. One pair goes in each sealed inner polyethylene bag, 15 inner bags go in each sealed outer bag, and six outer bags fill a lined carton of 90 pairs. The fabric is listed as a CleanTough polyethylene and non-woven polypropylene laminate in white, with bound seams, single-needle stitching, and an elasticated cuff. Ansell asks that the covers be stored dry, in their original packaging, away from direct sunlight.
Technical Specifications
| Manufacturer | Ansell |
| Series and model | BioClean-D S-BDSC-L |
| Product type | Sterile disposable long sleeve covers |
| Material | CleanTough, polyethylene and non-woven polypropylene laminate |
| Color | White |
| Length | 480 mm average (Ansell data sheet) |
| Size | Universal, long length |
| Fit | Integrated thumb loop; elasticated cuff |
| Construction | Bound seams with single-needle stitching |
| Static properties | Antistatic coating, charge half-decay time 0.07 seconds (Ansell data sheet) |
| Liquid repellence | Above 90 percent, index 3, ISO 6530, for four test liquids (Ansell data sheet) |
| Sterility | Sterile, gamma irradiation |
| Sterility assurance level | 10⁻⁶ |
| Shelf life | 3 years from date of manufacture |
| Standards listed | EN 13034:2005 + A1:2009; EN 1149-5:2018; ISO 11137-1:2006; ASTM F739 (partial body protection only); Category III; CE 0598; UKCA |
| Packaging | 1 pair per sealed inner PE bag; 15 inner bags per sealed outer PE bag; 6 outer bags per lined carton |
| Pack count | 90 pairs per case |
Applications / Common Uses
- Sterile gowning in life sciences. Ansell lists life sciences, and the gamma-irradiated pair arrives sterile with a sterility assurance level of 10⁻⁶.
- Aseptic zones. Listed for Class 10 (ISO 4) and EU GMP Grade A, the settings in which sterile garments are generally expected.
- Extra arm coverage. The 480 mm average length gives more coverage over the forearm than Ansell's standard sleeve covers.
- Staying in place during work. The integrated thumb loop keeps the sleeve from rolling back and exposing the wrist during reaching and handling.
- Static-sensitive handling. The antistatic coating, with a 0.07 second charge half-decay time, suits tasks where static could disturb parts or powders.
Storage, Handling & Shipping
The S-BDSC-L is supplied sterile and for single use, one pair per sealed bag. Ansell lists a shelf life of three years from the date of manufacture and asks that the covers be kept away from direct sunlight, stored in a dry place, and kept in the original packaging. Where aging or storage could affect the product, an expiry date is printed on the packaging.
- Keep each pair in its sealed inner bag until the moment of gowning to protect sterility.
- Use each pair once and discard it after use, following your site's waste rules.
- Check the expiry date on the packaging before opening a pair.
- Order by case: 90 pairs per case, one pair per inner bag.
Related Categories & Services
These LabPro pages help buyers compare these sterile sleeve covers with related products, choose companion items, and plan recurring supply.
- Sleeves: Sleeves, for added arm coverage where a separate sleeve cover is part of the gowning sequence.
- PPE Apparel & Garments: LabPro's overview of protective apparel and garments, a starting point for choosing between coverall, sleeve, and cover styles.
- Cleanroom Coveralls: LabPro's cleanroom coverall range, for comparing garment styles and sizes to pair with these sterile sleeve covers.
- VMI Program (service): LabPro's vendor-managed inventory program, relevant for teams that reorder these sterile sleeve covers on a regular schedule.
Related Articles
FAQs
How do the S-BDSC-L and BDSC-L sleeve covers differ?
Both are 480 mm long CleanTough sleeve covers with a universal long fit. The S-BDSC-L is sterile, sterilized by gamma irradiation to a sterility assurance level of 10⁻⁶, and sold as pairs, 90 to a case. The BDSC-L is non-sterile and sold as single pieces, 180 to a case.
How do I put on a sterile sleeve cover without touching the outside?
Handle the sleeve cover only by the inside opening and keep the outer surface away from your body and the floor. Slip your hand through, seat the integrated thumb loop, and draw the cover up the arm, then put on gloves per your site's sequence. Do not touch the outside.
Does the packaging come in more than one form?
Yes. Ansell lists the S-BDSC-L with one pair per sealed inner bag, 15 inner bags per outer bag, and six outer bags per carton. It also lists an S-BDSC-L2 form with a sealed double inner bag, 10 per outer bag, and nine outer bags. Both hold 90 pairs per carton.
What does EN 1149-5 on the listing mean?
EN 1149-5 sets material and design requirements for electrostatic dissipative protective clothing, and Ansell lists it for the S-BDSC-L sleeve cover alongside a 0.07 second charge half-decay time. It addresses static behavior only. It says nothing about sterility or cleanroom class, so check those listings separately for your room.
How many wearers does one case cover?
The case holds 90 pairs, and each sleeve cover pair is used once. One case therefore covers about 90 gowning sessions, or 90 wearers at one session each. Plan stock around the number of sterile gowning events per shift, since opened pairs are not reused.