What it is. Lab Pro's Acetone Cleanroom Grade Semi LP is a high-purity acetone (2-propanone, dimethyl ketone; CAS 67-64-1) supplied in 1-gallon fluorinated poly bottles for cleanrooms, commercial manufacturing, and laboratory research. It is intended for semiconductor, electronics, biotech, and chemical processing work, where a gallon of acetone must deliver consistent purity from lot to lot. The format suits benches and production lines that use acetone daily and need a controlled grade rather than hardware-store solvent.

Why the purity numbers matter. Lab Pro lists Acetone Cleanroom Grade Semi LP at a 99.97% assay, with residue after evaporation at 0.001% or less and water at 0.5% or less. In controlled environments, very low residue matters: once the solvent flashes off, virtually nothing is left behind to contaminate wafers, optics, or precision parts. Color is capped at 10 APHA, so the liquid stays clear and easy to inspect, and the tight specifications support repeatable results across batches.

How it cleans. Acetone is fully miscible with water and dissolves oils, greases, resins, waxes, and many organic residues, which is why it is a standard solvent for glassware cleaning and degreasing. It boils at about 133 °F and evaporates faster than isopropyl alcohol, so surfaces dry almost immediately and processes move quickly. That speed also means acetone is often used as a final rinse to pull water and residues off glassware before drying.

Packaging built for an aggressive solvent. Acetone attacks many plastics, so container choice matters. Lab Pro ships this cleanroom acetone in fluorinated poly bottles designed to resist chemical degradation and protect solvent integrity, sealed with a screw cap. Bottles travel in a fiber box with cardboard dividers that stop movement and damage in transit. Lab Pro's own guidance notes that acetone dissolves or damages ABS, polystyrene, and many acrylics but has little effect on polyethylene, polypropylene, and PTFE.

Safety profile buyers should know. Acetone is a Class IB flammable liquid: Lab Pro lists a flash point of -4 °F, so vapors can ignite well below room temperature, and NIOSH gives explosive limits of 2.5% to 12.8% in air. Its vapor is about twice as heavy as air and can travel to distant ignition sources. OSHA sets a permissible exposure limit of 1,000 ppm, and NIOSH recommends 250 ppm as an 8-hour average, so use acetone with ventilation and keep containers closed.

Intended use. Lab Pro's Acetone Cleanroom Grade Semi LP is intended for cleanroom use, commercial manufacturing, laboratory procedures, research, and general cleaning. It is not intended for pharmaceutical or medical device use. For chromatography and analytical work, Lab Pro also stocks Acetone HPLC Grade; for routine bench cleaning, Acetone Laboratory Grade in 4-liter bottles. Matching the grade to the process keeps costs in line while protecting the work that needs cleanroom-level purity.

Technical Specifications

Chemical Name Acetone (2-Propanone)
Synonyms Propanone, dimethyl ketone, methyl ketone, beta-ketopropane, pyroacetic ether
CAS Number 67-64-1
Formula (CH3)2CO
Molecular Weight 58.1
Grade MB, cleanroom grade (Semi LP)
Assay 99.97%
Appearance Clear liquid with characteristic odor
Color (APHA) 10 max
Water ≤0.5%
Residue after Evaporation ≤0.001%
Density 0.791 g/mL at 25 °C
Boiling Point 133.1 °F
Freezing Point -140 °F
Flash Point -4 °F (-20 °C), closed cup
Vapor Density (air = 1) 2
Vapor Pressure 180 mmHg
Explosive Limits LEL 2.5%; UEL 12.8%
Solubility in Water Miscible
Flammability Class Class IB flammable liquid
DOT ID UN1090
Exposure Limits OSHA PEL 1,000 ppm TWA · NIOSH REL 250 ppm TWA
Incompatible With Oxidizers, acids
Container 1-gallon fluorinated poly bottle, screw cap; fiber box with dividers
Not Intended For Pharmaceutical or medical device use

Applications / Common Uses

  • Semiconductor and electronics cleaning: removes organic residues from parts and tools with almost nothing left behind
  • Cleanroom surface and tool cleaning: a controlled, low-residue solvent for wipe-downs in controlled environments
  • Laboratory glassware cleaning and drying: dissolves organic residues and pulls water off glassware for fast drying
  • Degreasing in commercial manufacturing: strips oils, greases, waxes, and resins before bonding, coating, or assembly
  • Research and chemical processing: a high-purity solvent for laboratory procedures and research processes

Storage, Handling & Shipping

Store acetone in a cool, well-ventilated area approved for Class IB flammable liquids, away from heat, sparks, open flames, oxidizers, and acids. Keep the fluorinated bottle tightly closed in its original packaging to limit evaporation and contamination. Wear nitrile gloves and goggles, avoid breathing vapors, and ground containers during larger transfers because vapors can travel to ignition sources. Orders ship with a hazmat charge. Consult the SDS for full handling, exposure, and disposal guidance.

  • Storage: Flammable liquid storage area; cool, ventilated; away from ignition sources
  • Segregation: Keep apart from oxidizers and acids
  • Container: Fluorinated poly bottle with screw cap; keep tightly closed
  • Handling: Nitrile gloves and goggles; ventilate; ground during bulk transfers
  • Shipping: UN1090 flammable liquid; hazmat charge applies; next-day West Coast shipping