What it is. Lab Pro's Acetone Cleanroom Grade Semi LP is a high-purity acetone (2-propanone, dimethyl ketone; CAS 67-64-1) supplied in 1-gallon fluorinated poly bottles for cleanrooms, commercial manufacturing, and laboratory research. It is intended for semiconductor, electronics, biotech, and chemical processing work, where a gallon of acetone must deliver consistent purity from lot to lot. The format suits benches and production lines that use acetone daily and need a controlled grade rather than hardware-store solvent.
Why the purity numbers matter. Lab Pro lists Acetone Cleanroom Grade Semi LP at a 99.97% assay, with residue after evaporation at 0.001% or less and water at 0.5% or less. In controlled environments, very low residue matters: once the solvent flashes off, virtually nothing is left behind to contaminate wafers, optics, or precision parts. Color is capped at 10 APHA, so the liquid stays clear and easy to inspect, and the tight specifications support repeatable results across batches.
How it cleans. Acetone is fully miscible with water and dissolves oils, greases, resins, waxes, and many organic residues, which is why it is a standard solvent for glassware cleaning and degreasing. It boils at about 133 °F and evaporates faster than isopropyl alcohol, so surfaces dry almost immediately and processes move quickly. That speed also means acetone is often used as a final rinse to pull water and residues off glassware before drying.
Packaging built for an aggressive solvent. Acetone attacks many plastics, so container choice matters. Lab Pro ships this cleanroom acetone in fluorinated poly bottles designed to resist chemical degradation and protect solvent integrity, sealed with a screw cap. Bottles travel in a fiber box with cardboard dividers that stop movement and damage in transit. Lab Pro's own guidance notes that acetone dissolves or damages ABS, polystyrene, and many acrylics but has little effect on polyethylene, polypropylene, and PTFE.
Safety profile buyers should know. Acetone is a Class IB flammable liquid: Lab Pro lists a flash point of -4 °F, so vapors can ignite well below room temperature, and NIOSH gives explosive limits of 2.5% to 12.8% in air. Its vapor is about twice as heavy as air and can travel to distant ignition sources. OSHA sets a permissible exposure limit of 1,000 ppm, and NIOSH recommends 250 ppm as an 8-hour average, so use acetone with ventilation and keep containers closed.
Intended use. Lab Pro's Acetone Cleanroom Grade Semi LP is intended for cleanroom use, commercial manufacturing, laboratory procedures, research, and general cleaning. It is not intended for pharmaceutical or medical device use. For chromatography and analytical work, Lab Pro also stocks Acetone HPLC Grade; for routine bench cleaning, Acetone Laboratory Grade in 4-liter bottles. Matching the grade to the process keeps costs in line while protecting the work that needs cleanroom-level purity.
Technical Specifications
| Chemical Name | Acetone (2-Propanone) |
| Synonyms | Propanone, dimethyl ketone, methyl ketone, beta-ketopropane, pyroacetic ether |
| CAS Number | 67-64-1 |
| Formula | (CH3)2CO |
| Molecular Weight | 58.1 |
| Grade | MB, cleanroom grade (Semi LP) |
| Assay | 99.97% |
| Appearance | Clear liquid with characteristic odor |
| Color (APHA) | 10 max |
| Water | ≤0.5% |
| Residue after Evaporation | ≤0.001% |
| Density | 0.791 g/mL at 25 °C |
| Boiling Point | 133.1 °F |
| Freezing Point | -140 °F |
| Flash Point | -4 °F (-20 °C), closed cup |
| Vapor Density (air = 1) | 2 |
| Vapor Pressure | 180 mmHg |
| Explosive Limits | LEL 2.5%; UEL 12.8% |
| Solubility in Water | Miscible |
| Flammability Class | Class IB flammable liquid |
| DOT ID | UN1090 |
| Exposure Limits | OSHA PEL 1,000 ppm TWA · NIOSH REL 250 ppm TWA |
| Incompatible With | Oxidizers, acids |
| Container | 1-gallon fluorinated poly bottle, screw cap; fiber box with dividers |
| Not Intended For | Pharmaceutical or medical device use |
Applications / Common Uses
- Semiconductor and electronics cleaning: removes organic residues from parts and tools with almost nothing left behind
- Cleanroom surface and tool cleaning: a controlled, low-residue solvent for wipe-downs in controlled environments
- Laboratory glassware cleaning and drying: dissolves organic residues and pulls water off glassware for fast drying
- Degreasing in commercial manufacturing: strips oils, greases, waxes, and resins before bonding, coating, or assembly
- Research and chemical processing: a high-purity solvent for laboratory procedures and research processes
Storage, Handling & Shipping
Store acetone in a cool, well-ventilated area approved for Class IB flammable liquids, away from heat, sparks, open flames, oxidizers, and acids. Keep the fluorinated bottle tightly closed in its original packaging to limit evaporation and contamination. Wear nitrile gloves and goggles, avoid breathing vapors, and ground containers during larger transfers because vapors can travel to ignition sources. Orders ship with a hazmat charge. Consult the SDS for full handling, exposure, and disposal guidance.
- Storage: Flammable liquid storage area; cool, ventilated; away from ignition sources
- Segregation: Keep apart from oxidizers and acids
- Container: Fluorinated poly bottle with screw cap; keep tightly closed
- Handling: Nitrile gloves and goggles; ventilate; ground during bulk transfers
- Shipping: UN1090 flammable liquid; hazmat charge applies; next-day West Coast shipping
Related Categories & Services
- Solvents: acetone, alcohols, and other process solvents in bottles through drums
- Non-Sterile Wipers: cleanroom wipers to pair with solvents for wipe-downs
- Cleanroom Goggles: eye protection for solvent and chemical handling
- Gloves: exam, chemical-resistant, and cleanroom gloves
- Common Chemical Grades: a guide to choosing between ACS, USP, HPLC, and other grades
- Electronics Manufacturing industry page: Lab Pro products used in electronics manufacturing
Services
- Need recurring supply? Ask about Vendor-Managed Inventory (VMI) for standing orders of cleanroom solvents
- Punchout Catalogs: order through your procurement system
- Semiconductor Lab Startup Checklist: supplies checklist for new fab and electronics labs
Technical Library
CAS Number
67-64-1
FAQs
What is the difference between cleanroom-grade acetone and HPLC-grade acetone?
Cleanroom-grade acetone is made for low-residue cleaning in controlled environments, while HPLC-grade acetone is made for chromatography and analytical work. Cleanroom grades focus on residue after evaporation and particle control; HPLC grades focus on purity that will not interfere with detectors. Choose by the process, not the purity number alone.
Which plastics can safely hold or contact acetone?
Polyethylene, polypropylene, and PTFE resist acetone well and are common for bottles, wash bottles, and liners. Acetone dissolves or badly damages ABS, polystyrene, and many acrylics, and it can soften some coatings and elastomers. Check a chemical compatibility chart before using acetone on any plastic part or container. When in doubt, test first.
Why does acetone evaporate faster than isopropyl alcohol?
Acetone boils at about 133 °F, compared with about 181 °F for isopropyl alcohol, and it has a much higher vapor pressure. That makes it dry almost instantly, which speeds cleaning and glassware drying, but it also means vapors build up faster, so ventilation and closed containers matter more.
Which gloves hold up to acetone?
Thin disposable nitrile gloves give only brief splash protection against acetone and can break down quickly with continued contact. For longer handling, use gloves rated for ketone resistance, such as butyl rubber, and change any glove immediately after a splash. Check the glove manufacturer's chemical resistance data for acetone before choosing.
Can acetone be mixed with water for cleaning?
Yes, acetone is fully miscible with water, and diluted solutions are sometimes used for routine bench and equipment cleaning. Use full-strength cleanroom acetone when you need maximum solvency and the lowest residue. Prepare dilutions with deionized water and label containers with contents and concentration. Never store diluted acetone in unlabeled bottles.