Description
What it is. Ricca R9150000-20F is ACS Reagent Grade deionized water (H2O; CAS 7732-18-5) from Ricca Chemical Company that meets ASTM Type I and Type II reagent water standards. It comes in a 20-liter (5-gallon) plastic Cubitainer, a large format for analytical, pharmaceutical, and research labs that use reagent grade water every day and would rather buy certified water than run, monitor, and validate an in-house purification system for every application. Each container is ready to use without further treatment.
What the ASTM types mean. ASTM D1193 grades laboratory water from Type I, the purest, to Type IV. Type I water is used for the most critical work, such as instrumental analysis, standard preparation, and trace-level methods, while Type II covers general laboratory uses like buffer and reagent preparation and glassware rinsing. Ricca's certificate of analysis tests this water against the ACS reagent water requirements and ASTM D1193 Types I through IV, so one container covers both high-purity and everyday needs.
Purity you can document. Distributor listings for this SKU give a maximum conductivity of 0.056 µS/cm, the conductivity limit associated with ASTM Type I water. Each lot is supported by a Ricca certificate of analysis, and Ricca also publishes a Safety Data Sheet and a BSE/TSE statement for the product. That documentation trail is what separates laboratory grade water from distilled water bought off a shelf: auditors and method validations can trace exactly what went into a standard or sample.
Shelf life and handling. Ricca assigns this water an 18-month shelf life in its sealed container. Once opened, purity starts to drift: water absorbs carbon dioxide from the air, which lowers resistivity, and every dispensing step is a chance for contamination. Dispense with clean tools, keep the Cubitainer closed between uses, and reserve the freshest water for the most sensitive Type I work, using older opened stock for Type II tasks like rinsing.
Easy to ship and store. Unlike the solvents on a lab's shelf, ACS reagent water is not regulated for transport, so Ricca R9150000-20F ships without hazmat restrictions or fees. The collapsible Cubitainer stores compactly and is easy to dispense from at the bench. Ricca makes the water in the USA, and the same 9150 product line is offered in larger 55-gallon drums and 330-gallon totes for facilities with higher consumption. That makes it a simple item to keep in stock year-round.
Where it fits. Use Ricca ACS Reagent Grade water when a method, SOP, or standard specifies ACS or ASTM-certified reagent water, or when results must be traceable to a certificate of analysis. Lab Pro also stocks its own Deionized Water 18 MΩ Type I in 1-gallon and 5-gallon sizes, plus other Ricca waters such as ASTM Type II, Type III, and Type IV and molecular biology grade, so labs can match water grade to each task.
Technical Specifications
| Manufacturer | Ricca Chemical Company |
| Manufacturer Part Number | R9150000-20F (catalog 9150-5) |
| Chemical Name | Water, deionized |
| Chemical Formula | H2O |
| CAS Number | 7732-18-5 |
| Molecular Weight | 18.02 |
| Grade | ACS Reagent Grade |
| Standards | ASTM Type I and Type II (CofA tested to ASTM D1193 Types I–IV) |
| Conductivity | 0.056 µS/cm max (distributor specification) |
| Concentration | 100% |
| Appearance | Clear, colorless liquid |
| Container | 20 L (5 gal) plastic Cubitainer |
| Shelf Life | 18 months (sealed) |
| Transport | Not regulated for transport |
| Country of Origin | USA |
| Documentation | Certificate of analysis, SDS, BSE/TSE statement |
Applications / Common Uses
- Analytical and instrumental methods: Type I purity for standards, blanks, and trace-level analysis
- Reagent and buffer preparation: consistent, documented water for solutions and dilutions
- Pharmaceutical and QC labs: certified water traceable to a certificate of analysis
- Glassware final rinse: Type II use for rinsing without adding contaminants
- Research labs without in-house purification: certified water without running a purification system
Storage, Handling & Shipping
Store the sealed Cubitainer at room temperature away from direct sunlight, chemicals, and fumes that could contaminate the water. Once opened, keep it closed between uses and dispense with clean equipment to limit carbon dioxide uptake and contamination. Track the 18-month shelf life from the label, and reserve freshly opened water for the most sensitive applications. ACS reagent water is not regulated for transport and ships without hazmat fees.
- Storage: Room temperature; away from sunlight, chemicals, and fumes
- After opening: Keep closed; dispense with clean tools
- Shelf life: 18 months sealed
- Shipping: Not regulated for transport; no hazmat fee
Related Categories & Services
- Water: deionized and reagent-grade lab waters
- Buffers, Standards & Solutions: prepared solutions and standards for analytical work
- Analytical / Chromatography: supplies for HPLC and other analytical methods
- Common Chemical Grades: a guide to choosing between ACS, USP, HPLC, and other grades
- Chemicals & Reagents: the full range of lab and production chemicals, by grade and pack size
- Lab and Healthcare industry page: Lab Pro products used in lab and healthcare
Services
- Need recurring supply? Ask about Vendor-Managed Inventory (VMI) for standing orders of reagent water
- Punchout Catalogs: order through your procurement system
- New Lab Startups: help outfitting a new lab
Technical Library
FAQs
What is the difference between ASTM Type I and Type II water?
Type I is the highest purity grade under ASTM D1193, used for critical analytical work such as instrument calibration, standards, and trace analysis. Type II is slightly less pure and suits general lab work like reagent preparation and glassware rinsing. Ricca's water is certified to meet both.
Does reagent grade water stay pure after opening?
Not indefinitely. Once exposed to air, water absorbs carbon dioxide, which lowers resistivity, and each dispense risks contamination. Keep containers sealed between uses, dispense with clean tools, and use opened water first for less sensitive Type II tasks rather than critical Type I methods. Date containers when opened.
Is ACS reagent grade water the same as distilled water?
No. Distilled water is purified by boiling and condensing, but it is not necessarily tested to a defined standard. ACS reagent grade water is tested against published ACS and ASTM specifications and supported by a certificate of analysis, which is what methods and audits require. Distilled water may still suit routine rinsing.
Is this water sterile?
The sources reviewed do not describe this product as sterile. For sterile applications, choose water specifically labeled sterile, such as molecular biology grade or sterile-filtered water, and confirm with the certificate of analysis before using it in cell culture or other sterile work. Ricca offers sterile waters separately.
When should a lab buy reagent water instead of making it?
Buying certified water makes sense when volumes are modest, a method requires documented ACS or ASTM compliance, or maintaining and validating a purification system isn't practical. High-volume labs often run their own systems and keep certified water for critical methods and system checks. Many labs use both approaches.