Description
What it is. The Estatec Estashoe 4.0 is a lightweight white EVA ESD shoe that grounds the wearer through the floor, built for electronics assembly, cleanrooms, and other static-sensitive areas. This listing is the 29 cm size, men's 11 and women's 12, part number ESH-B429. Estatec designs the Estashoe in a clog style that slips on quickly, so operators get continuous grounding without the straps, cords, or heel grounders other ESD footwear requires.
How ESD shoes work. Static builds up on a person as they walk and move. ESD shoes give that charge a controlled path to ground: the ESD shoe uses a dissipative insole in contact with the foot and a conductive, anti-slip rubber outer sole that contacts an ESD floor. Charge drains continuously from the body to the floor, so the wearer stays near ground potential instead of carrying a charge that could discharge into sensitive components.
Why the 2 megohm resistor matters. Estatec builds a 2 megohm resistor into the grounding path. That resistance limits how much current can flow through the wearer if they touch a live electrical source, providing protection against electrical shock while still allowing static to drain. This balance between fast static control and personnel safety is the reason ESD footwear uses a defined resistance rather than a direct short to ground. It is a standard design choice in quality ESD footwear for electronics work.
Comfort for long shifts. EVA keeps the Estashoe lightweight, flexible, and soft while staying durable, and the ergonomic design includes a comfortable ESD insole for operators who stand or walk through long shifts. The material is water repellent and resistant to bacteria and fungi, which suits facilities with strict hygiene requirements. Estatec also offers vented versions for added airflow; this model is the standard white Estashoe 4.0. Comfortable shoes also make it more likely operators keep them on all shift.
Cleanroom-ready. Estashoes can be used in cleanrooms. The smooth EVA surface cleans easily with a cloth, soap, and water between uses, so shoes can be kept dedicated to a controlled area. For additional particle control, wear them with cleanroom socks. The white color also makes dirt and wear easy to spot during routine inspections, helping teams decide when a pair needs cleaning or replacement. Keeping a spare pair per operator helps rotate cleaning without downtime.
Choosing size and verifying grounding. Estashoes are offered in whole centimeter sizes from 23 to 29 cm; half sizes are not made, so choose the closest whole size. This 29 cm shoe corresponds to men's 11 and women's 12. ESD footwear only works on a conductive or dissipative floor, so pair Estashoes with an ESD floor and check each operator with a footwear tester at the start of every shift. Logging test results supports ESD program audits.
Technical Specifications
| Manufacturer | Estatec |
| Model | Estashoe 4.0 |
| Part Number | ESH-B429 |
| Color | White |
| Size | 29 cm (Men 11 / Women 12) |
| Upper Material | EVA |
| Insole | Dissipative ESD comfort insole |
| Outsole | Conductive, anti-slip rubber |
| Resistance | 2 megohm resistor in grounding path |
| Style | Clog, slip-on |
| Cleanroom Use | Yes; wear with cleanroom socks for added particle control |
| Properties | Water repellent; resistant to bacteria and fungi |
| Cleaning | Cloth, soap, and water |
| Size Range (line) | 23–29 cm, whole sizes only |
| Pack | 1 pair |
Applications / Common Uses
- Electronics assembly: grounding operators handling static-sensitive components
- Cleanrooms: easy-to-clean ESD footwear for controlled areas
- Semiconductor and device manufacturing: continuous personnel grounding on ESD floors
- Laboratories: static control in instrument and electronics labs
- Repair and rework stations: hands-free grounding while moving around the work area
Storage, Handling & Shipping
Store ESD shoes clean and dry, away from heat sources that can deform EVA. Clean with a cloth, soap, and water, and let them dry before use. Keep shoes dedicated to ESD-protected or cleanroom areas to avoid tracking in contamination. Test grounding with a footwear tester at the start of each shift and replace shoes that fail testing or show worn soles.
- Storage: Clean, dry; away from heat
- Cleaning: Cloth, soap, and water
- Testing: Footwear tester check at the start of each shift
- Replace: When testing fails, or soles are worn
Related Categories & Services
- ESD & Static Control: ESD footwear, smocks, ionizers, and grounding products
- Cleanroom Socks: socks to wear with cleanroom and ESD footwear
- ESD Smocks: static-control smocks to pair with ESD footwear
- ESD Ionizers: ionizers that neutralize charge on insulators
- Controlled Environment Chairs: cleanroom and ESD seating
- Electronics Manufacturing industry page: Lab Pro products used in electronics manufacturing
Services
- Need recurring supply? Ask about Vendor-Managed Inventory (VMI) for standing orders of ESD footwear and supplies
- Punchout Catalogs: order through your procurement system
- Semiconductor Lab Startup Checklist: supplies checklist for new fab and electronics labs
Technical Library
FAQs
Do ESD shoes work on any floor?
No. ESD shoes need a conductive or static-dissipative floor to drain charge to ground. On standard vinyl, carpet, or sealed concrete, the charge has nowhere to go. Pair ESD footwear with an ESD floor or grounded floor mats in work areas. Check floor resistance as part of your ESD program.
What is the difference between conductive and dissipative footwear?
Conductive footwear has very low resistance and drains charge fastest, while dissipative footwear has higher resistance, drains charge more slowly, and limits current. The Estashoe uses a conductive sole with a 2 megohm resistor in the path, combining effective grounding with protection against electrical shock. Both types require an ESD floor to work.
How often should ESD shoes be tested?
Test each operator's footwear at the start of every shift, or each time they enter an ESD-protected area, using a footwear or combination tester. Testing confirms the full path from body to floor works, which can change with dirt, worn soles, or socks. Keep a log of results for audits.
What are ESD shoes?
ESD shoes are footwear designed to drain static electricity from the wearer to a grounded ESD floor, keeping the body near ground potential so it cannot discharge into sensitive electronics. They use conductive or dissipative soles, and many, like the Estashoe, include a resistor to protect the wearer from electrical shock.
How do I choose the right Estashoe size?
Estashoes come in whole-centimeter sizes, measured by foot length, with no half sizes. Measure your foot length in centimeters and choose the nearest whole size. This 29 cm shoe fits men's 11 and women's 12; the 28 cm size fits men's 10 and women's 11. Try shoes on with work socks.