Minimum 1
$16,000.00
| Features: |
| Integral base with deep spill lip |
| Wide range of bonded activated carbon and HEPA filters for containment of virtually any toxic vapor, fume, gas, or particulate |
| AirZone baffling establishes a proper horizontal airflow pattern and directs toxins away from the operator in a predictable pattern, eliminating "dead spots" within the hood |
| Vertical sliding safety glass sash |
| Dual wall construction allows for front mounting of services such as water, gas, or electric |
| Constant monitoring of fume hood face velocity with variable airflow control to user preset value |
| Large capacity filtration bed to handle a wide variety of applications |
| Touch-screen microprocessor control with variable airflow controller and constant filter monitoring |
| ChemMinder™ chemical class confirmation - user notification of chemical/filtration compatibility |
| Lab event timer |
| Gas phase bonded carbon filtration |
| Benefits: |
| Filter safety lockout to ensure correct filter replacement |
| AirZone™ baffling to prevent fume hood roll and provide superior containment of gases and vapors |
| Electronic gas detection for real-time gas phase filter monitoring |
| Tested to UL 61010-1,CSA C22.2 No. 61010-1, and EN 61326-1 |
| Deep base effectively contains accidental spills |
| Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas |
| Low airflow alarm warns the user both visually and audibly |
| ASHRAE 110 tested |
| Real time monitoring of installed filtration bed |
Minimum 1
$16,000.00
| Features: |
| Integral base with deep spill lip |
| Wide range of bonded activated carbon and HEPA filters for containment of virtually any toxic vapor, fume, gas, or particulate |
| AirZone baffling establishes a proper horizontal airflow pattern and directs toxins away from the operator in a predictable pattern, eliminating "dead spots" within the hood |
| Vertical sliding safety glass sash |
| Dual wall construction allows for front mounting of services such as water, gas, or electric |
| Constant monitoring of fume hood face velocity with variable airflow control to user preset value |
| Large capacity filtration bed to handle a wide variety of applications |
| Touch-screen microprocessor control with variable airflow controller and constant filter monitoring |
| ChemMinder™ chemical class confirmation - user notification of chemical/filtration compatibility |
| Lab event timer |
| Gas phase bonded carbon filtration |
| Benefits: |
| Filter safety lockout to ensure correct filter replacement |
| AirZone™ baffling to prevent fume hood roll and provide superior containment of gases and vapors |
| Electronic gas detection for real-time gas phase filter monitoring |
| Tested to UL 61010-1,CSA C22.2 No. 61010-1, and EN 61326-1 |
| Deep base effectively contains accidental spills |
| Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas |
| Low airflow alarm warns the user both visually and audibly |
| ASHRAE 110 tested |
| Real time monitoring of installed filtration bed |